Building Cogeneration of Electricity-Heating and Cooling at MAILLIS industry

MAILLIS industry with Natural Gas combustion substitudes the consumed electricity for plastic formation, though with the engines jacket heat recovery, cool water is produced for the cooling of the final products and with the produced steam through the exhaust system opearate the PICLING unit of the sheetmetal shop.

PROJECT: BUILDING COGENERATION OF ELECTRICITY-HEATING AND COOLING IN MAILLIS INDUSTRY
END USER: M.J. MAILLIS SA
START-UP YEAR: 2001
ENGINE TYPE: GE WAUKESHA, VGF P48GLD 700KW
CHILLER TYPE: LG CABLE 340RT, SINGLE STAGE HOT WATER
STEAMER TYPE: CLAYTON 500ΚG/HR, 8BARG
APPLICATION: TRIGENERATION IN INDUSTRY
FUEL: NATURAL GAS
LOCATION: CONTAINER
POWER ELECTRIC POWER: 2,100KW, STEAM POWER: 1,100KW, COOLING POWER: 340RT